You can read all the about the Mixergy cylinder installation and Plant Room project here:
The cylinder project was completed 9 months prior to the heat pump going in, which meant I ran the Mixergy on a combination of overnight cheaper tariff electricity and PV diversion from our Solar and myenergi Eddi diverter. This worked very well through the summer, but we wanted the heat pump in before the winter when solar generation drops off dramatically.
The 5kW heat pump replaced a 32kW Vaillant Ecotec combi-boiler as part of the government boiler upgrade scheme.
Note: the combi had plenty of life in it and was passed onto someone else to use. So not scrapped.
All heating and plumbing work was undertaken by Damon Blakemore Plumbing, Heating and Renewables in Sheffield.
https://blakemoreplumbingandheating.co.uk/
The install was completed as part of the Heat Geek assured scheme.
https://www.heatgeek.com/heat-geek-assured/
And all electrical work was done by Mike Haver of Practical Property Services.
After the first winter, we made two more radiator changes that left us with the following configuration going into the second winter.
Design Outside Temperature: -2.5℃ (Sheffield at 100m elevation)
Design outside temperature (DOT) targets:
Full details of the design, measurements, calculations about the heat loss and before/after diagrams are all included in my ‘What size heat pump?’ article.
Absolutely NOT. When heating there is a hum from the Arotherm heat pump. But it is drowned out by road noise, birds tweeting and wind blowing in the trees.
When doing a hot water run, i.e. when it’s working harder. The noise does go up a notch, but you still can’t hear it from a few metres away.
It has certainly passed both the wife test and the neighbours too.
Honestly, my neighbours combi boiler is noisier than my heat pump.
All of these concerns should be addressed early doors during the MCS noise impact assessment. ie, distance from neighbours windows, dB output of the heat pump, any barriers in the way etc.
This is all covered in the MCS permitted planning document MCS 020.
https://mcscertified.com/wp-content/uploads/2021/10/MCS-020.pdf
You can read all about the various monitoring options over at Open Energy Monitor.
https://guide.openenergymonitor.org/applications/heatpump/
They provide solutions for heat pumps, solar or just plan home/grid usage.
Their heat pump application gives a simple interface showing live and historical view provided COP (coefficient of performance) as shown here.
You can also view historical monitoring data directly from my heat pump via the following public link
https://emoncms.org/energystatsuk/
My installation is listed alongside a whole host of the other heat pumps being monitored via the Open Energy Monitoring platform.
You can find them listed at the heatpumpmonitor website.
This is an open source endeavour looking to include a variety of make/models of heat pumps in all different build types of homes.
During the years of installing the Mixergy and heat pump we have been improving insulation in rooms where we can. Notably a front bedroom bay window and the floor in the dining room.
You can see historical Solar generation data of my system going back to November 2018 here.
Absolutely, YES.
Heat pumps do work when it’s cold outside.
Below is a 30 hour snapshot from December 2022 where the temperature averaged -1℃ across the whole period with a low of -3.1℃
As you can see, the heat pump worked flawlessly putting the required amount of kW of heat into the house to maintain 19℃ to 21℃ indoors.
Including the hot water runs (the large spikes) we managed a COP (coefficient of performance) of 2.67 across that window. Remember, a gas combi boiler will work somewhere around 0.8 / 0.85 if condensing.
As I’ve stated many times, the heat pump performance is all down to sizing the heat pump correctly. It’s all about the design, the heat loss survey, the primary pipe work and the emitter sizing (radiators or underfloor).
All of which is covered in the What Size Heat Pump article.
In the first whole year the figures looked like this:
It is September of the second whole year and we are already at a COP of 4.12, so slight system tweaks have improved things.
You can read about the improvements we made in the “First Winter” and “Second Winter” articles listed below.
You can also look at month by month performance figures of the Heat Pump going to back to November 2022 in this post.
There are a whole host of useful articles in my Blog, especially if you have a Vaillant Arotherm and you want to know more about how it works.
The following articles listed below are also recommended if you want to see more “Real World” data and experiences of a family of four living with a heat pump in a 1930 semi-detached house in Sheffield.
If you find the content of this website useful and are thinking of joining Octopus Energy, please consider using my referral code or ‘buy me a coffee’ to help support running costs of the website (hosting fees / cloud servers etc).
Using this referral code will gift you £50 of free Octopus Energy credit after signup: https://share.octopus.energy/linen-pearl-869
If you would like to ‘buy me a coffee’ to show support, please use this link: http://buymeacoffee.com/SVHgIbUYM
If you’re considering owning part of a wind farm through Ripple Energy, get £25 of free credit (if investing more than £1000) using my Ripple referral link.
Energy Stats can also be found on Twitter / X. Please follow us @energystatsuk for daily tariff pricing graphs and summaries.
We have also started posting the same graphs over on Mastodon. You can find us here: https://mastodonapp.uk/@energystatsuk