Skip to main content

Vaillant Arotherm Heat Pump Guide: Weather Curve, Hot Water Modes, SensoCOMFORT, COP & SCOP

Introduction

If you own a Vaillant Arotherm Plus heat pump—or are considering one—getting the most out of it is all about setup, monitoring, and fine-tuning.

This guide compiles key insights from Energy Stats UK to help you optimise your Vaillant weather compensation curve settings, select the right hot water mode, master the SensoCOMFORT controller, and accurately measure COP & SCOP.

In this Vaillant Arotherm Heat Pump Guide we’ll also cover known firmware issues, model performance differences, and real-world seasonal results—so you can boost efficiency, cut costs, and avoid common pitfalls.

Vaillant Arotherm Heat Pump Guide
Vaillant Arotherm Heat Pump Guide

1. Weather Compensation Curve for Vaillant Arotherm

The Vaillant weather compensation curve adjusts your system’s flow temperature according to the outdoor temperature.

  • Why it matters: Lower flow temperatures mean higher COP and lower running costs.

  • How to set it: On the SensoCOMFORT controller, choose a slope that matches your home’s heat loss profile and system design.

  • Heek Geek Pro tip: Gradually reduce the curve value over a number of days until you are cold, then put it back up one value.

2. SensoCOMFORT Controls & Room Temp Mod Settings

The Vaillant SensoCOMFORT Room Temp Mod function influences how the weather curve responds to actual indoor temperature.

  • Inactive: Uses weather curve only.

  • Active: Blends indoor sensor feedback with the weather curve for smoother control—ideal for most UK homes.

  • Expanded: Runs like Active, but also acts more like a thermostat, stopping heating when the target indoor temperature is reached.

You may also want to consider a remote control optimiser like Havenwise that can make automatic curve and temperature decisions for you as well as schedule hot water runs at the cheapest times.

SensoCOMFORT Room Temp Mod: Inactive, Active or Expanded?

3. Hot Water Modes Explained (Eco, Normal, Balance)

The Vaillant hot water mode comparison: Eco vs Normal vs Balance shows how each setting affects recovery time and efficiency:

  • Eco mode: Slower but most efficient, capping compressor speed.

  • Normal mode: Fastest recovery, highest power use.

  • Balance mode: Starts like Normal, switches to Eco near target temperature.

Arotherm Plus Hot Water Modes

4. Hot Water Performance, “Sweet Spot” Mode and Cylinder Sizing

Analysis of real-world Eco mode COP for Vaillant Arotherm shows that Eco delivers the highest SCOP for hot water—often above 3.8—but recovery can be slow, especially with larger cylinders.  Which was explained in the The Problem With Eco Mode Hot Water Mode article.

The Vaillant Sweet Spot hot water mode guide explains how limiting compressor speed to around 80 rps achieves recovery roughly 30% faster than Eco with only a small drop in efficiency.

You may also wish to read The Heat Pump Hot Water Golden Rules which describes which are the best settings for heat pump hot water to get the best performance.

The final hot water related article that could be of interest is the Hot Water Cylinder Sizing and Mixing guide.

The Problem with Eco Hot Water Mode

Vaillant Arotherm Sweet Spot Hot Water Mode

The Heat Pump Hot Water Golden Rules

Hot Water Cylinder Sizing and Mixing

5. Measuring Vaillant COP & SCOP

  • COP (Coefficient of Performance): Real-time efficiency—heat output divided by electrical input.

  • SCOP (Seasonal COP): Average performance over a season.
    Learn exactly how to measure Vaillant heat pump COP and SCOP using the Yield Indicator menu.
    Example: At 35 °C flow temperature, SCOP can exceed 4.4, but drops near 3.0 at 55 °C.

How to Measure Vaillant Arotherm COP

6. Firmware Issues & Fixes

Firmware 351.06.07 Energy Integral bug explained shows how a cycling error reduced efficiency.

  • Fixed in 351.09.01 and 351.09.02—worth updating if you have an older version.

  • Firmware 351.06.07 also ignores “Compr.start heat.from” after the first heating cycle.

Vaillant Arotherm Firmware 351.06.07 Problems (Energy Integral)

7. Performance Differences Between Models

Datasheets comparing smaller Vaillant heat pumps vs larger models performance confirm that 3.5 kW and 10 kW units are software-limited versions of the larger 5 kW and 12 kW systems.

While the hardware is similar, larger Arotherm models tend to achieve higher SCOP than their smaller counterparts.

Smaller Heat Pumps will never reach Top of the SCOPS

8. Real-World Winter Performance Review

From November 2024 to April 2025, a 5 kW Arotherm Plus recorded:

  • SCOP Combined: 4.0

  • Heating SCOP: 4.2

  • Hot Water SCOP: 3.5

The third winter performance results for Vaillant Arotherm Plus also show that even during a –2.9 °C average day, heating COP stayed near 2.87. Firmware updates reduced cycling, further improving seasonal efficiency.

You may also find value looking back at my previous winter season summary articles; First Winter With My Air Source Heat Pump and Second Winter with our Vaillant ASHP.

As well as a monthly usage and performance breakdown going back to October 2022 in the Heat Pump Performance History article.

Third Winter with our Vaillant Heat Pump

Heat Pump Performance History

9. Use Time Of Use Tariffs to reduce running costs

Time-of-use (ToU) tariffs can significantly reduce your running costs if your Vaillant Arotherm Plus is set up to make the most of cheaper off-peak electricity rates. By scheduling hot water heating or boosting buffer storage during low-cost periods, you can improve your overall seasonal performance factor and lower bills.

We covered many of the Octopus Energy tariff options in this Best Heat Pump Tariff article.

As well as a Summary of Octopus Energy Smart Tariffs including Agile, Tracker, Intelligent Go and Cosy.

Tip: Pair ToU Tariffs with weather compensation and hot water scheduling for maximum savings without sacrificing comfort.

Best Heat Pump Tariff

Vaillant Arotherm Heat Pump Guide Conclusion

By fine-tuning the Vaillant weather compensation curve, selecting the right Room Temp Mod, choosing efficient hot water modes, and keeping firmware up-to-date, you can significantly improve your Vaillant Arotherm heat pump’s COP and SCOP.

For deeper dives into each topic, explore the full set of heat pump and solar resources at Energy Stats UK.

Referral information and free credit offer

If you find the content of this website useful and are thinking of joining Octopus Energy, please consider using my referral code or ‘buy me a coffee’ to help support running costs of the website (hosting fees / cloud servers etc).

If you’re thinking of switching energy suppliers, homeowners that use this referral code can claim £50 of free Octopus Energy credit after sign-up: https://mickwall.octopus.energy

Business users that switch and sign-up using the same code with be granted £100 of free credit.

Get a £100 gift card when signing up for Solar or a Heat Pump installation through Octopus Energy using this link: https://tech.referrals.octopus.energy/ucMTeP8d

If you would like to ‘buy me a coffee’ to show support, please use this link: http://buymeacoffee.com/SVHgIbUYM

Energy Stats UK can be found on various social media platforms posting daily tariff pricing graphs and summaries.

Be sure to follow @energystatsuk on Twitter / X, Bluesky, Mastodon and Instagram.

Note: The current and past performance of energy pricing is not necessarily a guide to the future.

77 Comments

Leave a Reply